01. Innova 1512

INNOVA 1512

Highly Accurate, Stable, Quantitative, and Remotely Controllable Gas Monitoring System

More details 

--

More details

Advanced Energy's Innova 1512 is based on the photoacoustic infrared spectroscopy and delivers superior sensitivity in a very compact form factor. Extremely versatile by design, the 1512 is capable of measuring almost any gas that absorbs infrared light.

-------

It is a highly accurate, reliable, and stable quantitative gas monitoring system. Its measurement system, based on the photoacoustic infrared detection method, is capable of measuring almost any gas that absorbs infrared light.

--------

Gas selectivity is achieved through the use of optical filters. By installing up to five filters, the 1512 can measure the concentration of up to five component gases and water vapor in any air sample. The detection limit is gas-dependent, but is typically in the ppb region. Accuracy of these measurements is ensured by the 1512’s ability to compensate for temperature and pressure fluctuations, water vapor interference, and interference from other gases known to be present.

--------

-   Leverages the unique strengths of the photoacoustic sensor technique
-   User-friendly, stable, reliable, and highly accurate
-   Extremely low-volume flushing possible

----

Benefits

- Selectively measure a wide range of gases / vapors
- Ensure a maximum of only two calibrations a year
- Operate immediately with virtually no warm-up time necessary
- Easily calibrate, configure, and view / analyze data via PC
- Accurately compensate for temperature and pressure fluctuations, water vapor interference, and interference from other known gases

S&V 

----

Features

- Linear response over a wide dynamic range

- Remote control capability via TCP/IP network interface protocol

- Expandable up to 24 locations with Innova 1409 Multipoint Sampler; the gas monitor can operate as the system controller

  for full standalone operation

- Includes BZ7002 calibration software

- Includes BZ7003 offline software to set up the gas monitor without connecting it to a PC and to download data

   stored in the gas monitor's internal memories

-----

S&V

Measurement Specfication 

Detection Limit 

Gas dependent, but typically in the ppb region; using the Gas Detection Limits Chart, the detection limit for a selected sample integration time (SIT) can be calculated

---

Dynamic Range

Typically four orders of magnitude (i.e., 10,000 times the detection limit at 5 SIT); using two span concentrations it can be expanded to five orders of magnitude

----

Repeatability

 1% of measured value

Measured at 20°C, 1013 mbar, and relative humidity (RH): 60%; a concentration of 100x detection limit (5s SIT) was used in determining these specifications

-----

Interference

The 1512 automatically compensates for temperature and pressure fluctuations in its analysis cell and can compensate for water vapor in the air sample; if an optical filter is installed to measure a known interferent, the 1512 can cross compensate for the interferent. 

-----

Internal Data Storage Capacity

The total space available in display memory to store data ia 131072 measurement cycles; if a measurement cycle takes 15 sec, then the display Memory space will be sufficient for a 22-day monitoring task

-----

-----

INNOVA 1512 Data Sheet 

Application Notes for Ventilation 

Back To The Innova Product List 